产品详情
  • 美国hausser howard mold霍华德霉菌计数板 上海拜普发展实业有限公司-凯发app官方网站

  • 产品型号:美国hausser howard mold霍华德霉菌计数板
  • 产品厂商:其它品牌
  • 产品价格:0
  • 折扣价格:0
  • 产品文档:
你添加了1件商品 查看购物车
简单介绍:
美国hausser howard mold霍华德霉菌计数板美国hausser howard mold霍华德霉菌计数板美国hausser howard mold霍华德霉菌计数板美国hausser howard mold霍华德霉菌计数板
详情介绍:

产品特点:

l  美国hausser scientific血球计数板,霍华德霉菌计数板,准确计算白细胞、红细胞、血小板、组织培养细胞、细菌和精子

l  the counting chamber is of all glass construction. in the center of the slide is a rectangle 15 x 20 mm, which is flanked by shoulders on each side 0.1mm higher. the cover glass is supported on these shoulders and leaves a depth of 0.1mm between the underside of the cover glass and the rectangle. the rectangle and the cover glass have optically plane surfaces. to facilitate calibration of the microscope, the rectangle has two engraved parallel lines spaced 1.382mm apart.

l  an accessory eyepiece micrometer is available which is ruled into squares, each of which is equal to 1/6 of the diameter of the eyepiece diaphragm opening. for mold counting, the microscope must give an area of 1.5 sq. mm.(circle 1.382 mm in diameter) at magnification of 90-125.

l  tomato products
(not dehydrated) #42.57

l  in making mold counts of tomato products, use juice and catsup as it comes from the container. if necessary add clean, mold free, water-soluble gum to assist in making more uniform mounts; in case of puree and paste mix h2o to make total tomato solids of diluted product 8.37-9.37%.

l  clean the howard cell so that the newton rings are produced between slide and cover glass. remove cover glass and place small drop of well mixed sample upon central rectangle; using knife blade or scalpel, spread drop evenly over rectangle, and cover with glass so as to give an even spread. use only sufficient sample to bring material to edge of rectangle. (it is of utmost importance that the drop be taken from a thoroughly mixed sample and spread evenly over rectangle. otherwise, when cover slip is put in place, insoluble material, and consequently molds, may be more abundant at the center of mount). discard any mount showing uneven distribution or absence of newton rings, or liquid that has been drawn across moat and cover glass.

l  place slide under microscope and examine with such adjustment that each field of view covers 1.5sq. mm. which is a circle with a diameter of 1.382 mm.. this adjustment can be facilitated by use of the two parallel lines engraved at the side of the rectangle which are spaced 1.382 mm apart. when the instrument is properly adjusted, quantity of liquid examined per field is 0.15 cu. mm..

l  from each of two or more mounts examine at least 25 fields taken in such manner as to be representative of all sections of mount. observe each field, noting presence of absence of mold filaments and recording results as positive or negative, as case may be. (no field should be considered positive unless aggregate length of not more than 3 of filaments present exceeds 1/6 of diameter of field which is equal to the distance between any to lines of the howard eyepiece micrometer). calculate proportions of positive fields from results of examination of all observed fields and report the percentage of fields containing mold filaments. in case greater accuracy is desired more fields should be counted.

l  rot in canned tomatoes #42.60

l  drain contents of can 2 min. on no. 2 sieve. for containers less than 3 lbs. net weight, use sieve 8" in diameter; for containers of 3 lbs. or more net weight, use 12" sieve. examine drained tomatoes and record number and size of any rotten portions present. run drained tomatoes through laboratory cyclone with screen openings ca 0.027" in diameter, or brush through no. 30 sieve with stiff-bristle brush. make mold counts on both drained juice and pulped tomatoes as directed in 42.57.

l  tomato soup, canned spaghetti,

l  pork and beans, and similar

l  products containing tomato sauce #42.64

l  tomato soup with or without cream. -place can in hot h2o and heat until contents are thoroughly warmed; then open. transfer 10 ml of thoroughly mixed soup to 50 ml centrifuge tube and add 3 ml of koh soln. (1x1). stir until starch in soup has been dissolved and tissues cleared. add sufficient h2o to fill tube, and centrifuge. (time required to centrifuge sample varies greatly. with centrifuge arm length of 5¼" and at speed of ca 1600rpm, ca 20 minutes is required for average sample. in heavy soups the gelatinizing of so much starch sometimes interferes with proper settling out of solids during centrifuging. if liquid remains cloudy it may be necessary to discard sample and start again with only 5 ml of soup and proceed with the usual 3 ml of koh). when supernatant liquid is clear, pour it off. if it is not entirely clear, check supernatant liquid for mold before discarding. add enough h2o to residue in tube to bring to original volume of soup, mix, and count mold as directed in 42.57.

l  pork and beans, spaghetti with sauce, spaghetti with meatballs or meat, ravioli, chili con carne, and tamales. - place unopened can in hot h2o and heat until contents are thoroughly warmed. open can and transfer contents onto no. 6 sieve. drain until major portion of liquid part has passed through. (with some products sauce runs through at once, but in case of some beans and spaghetti 10 or more minutes may be required). mix sauce thoroughly, place 10 ml in centrifuge tube, and proceed as directed in (a). use care in products containing meat so as not to confuse mold filaments and muscle fibers that bear a superficial resemblance to each other; muscle fibers are usually much thicker and striations are often visible.

l  sardines or other fish with tomato sauce - heat can in boiling h2o and drain off sauce as directed in (b). mix sauce thoroughly and place portion in centrifuge tube. discard oil and treat 10 ml of well-mixed sauce with 3 ml of koh soln. as directed in (a). use care to differentiate between mold filaments and muscle fibers from the fish. count as directed in 42.57.

l  dehydrated tomato

l  products # 42.65

l  tomato juice cocktail - if possible, ascertain formula used in making the dehydrated cocktail, and from it calculate approximate percentage of tomato solids. multiply this percentage by 34.36. resulting figure will be ml of solvent to be used to dilute 2 g of the dehydrated cocktail in preparation for mold counting. (dilution factor is based on tomato solids content of 5.5% for tomato juice).

l  weigh 2 g of well-mixed sample into 50 ml beaker and add 50 ml h2o. determine weight of sample, including beaker and stirring rod, before any moisture is lost by heating. heat mixture on steam bath 10-15 minutes. weigh beaker and add h2o to replace moisture lost by heating. add sufficient 4% pectin soln. to make up the difference between 15 ml and calculated volume of liquid needed for the dilution. mix thoroughly and proceed as directed in 42.57.

l  if formula or tomato solids content of product is not available, make dilutions for mold counting by adding a quantity of h2o and the pectin soln. (half and half) equal to amount of liquid specified in directions for preparing product for consumption. dissolve flakes as directed above and proceed as directed in 42.57.

l  tomato flakes and tomato soup flakes - ascertain if possible formula used in making the flakes, and from it calculate approximate percentage of tomato solids. multiply this percentage by 21.88. resulting figure will be ml of chloral hydrate soln. needed to dissolve 2 g of the dehydrated product in preparation for mold counting. (dilution factor is based on tomato solids content of 8.37% for tomato puree).

l  if product is tomato flakes containing added starch but no added water-soluble solids, determine approximate total tomato-solids content of dry mixture by testing definite dilution with refractometer and converting reading to tomato solids. if reading is in soluble solids, make correction to insoluble tomato solids, which are ca 1% in cyclone juice. (soluble solids for cyclone juice average ca 4.7%)

l  weigh 2 g of well-mixed sample in 50 ml beaker and add calculated volume of chloral hydrate soln (1x1). determine weight of sample, including beaker and stirring rod, before any moisture is lost by heating. boil mixture gently, stirring 5 minutes or until it has gelatinous appearance. (too much clearing of mixture makes it difficult to see the mold ). weigh beaker and add h2o to replace lost moisture. mix thoroughly, and if the mixture remains milky heat almost to boiling, stirring constantly. proceed as directed in 42.57.

l  if the formula or tomato-solids content of product cannot be ascertained, dilutions for mold counting may be made on basis of 80% tomato solids for tomato flakes and 40% tomato solids for tomato soup flakes.

l  rot (based on mold count) #42.85

l  weigh out 10 g of thoroughly mixed sample of ground capsicum and transfer to waring blender or equivalent mixer. add 200 ml of 1% naoh slon in 3 or 4 successive portions, stirring mixture after each addition, washing down with final portion any material that may stick to walls of blender. agitate mixture in blender 1 minute. with rubber policeman rub down into mixture any material sticking to walls of blender and repeat blending 2 minutes longer. add 2 or 3 drops capryl alcohol to break resulting foam. mix 100 g of this mixture with 50 g of 3% pectin soln, and count with howard mold-counting cell as directed under 42.57.

l  occasionally a blended mixture will contain particles of seed tissue that make it difficult to obtain newton rings in preparing slide for mold counting. a clamp devised for holding cover slip in place to obviate this difficulty consists of metal plate with circular opening, 2.5 cm in diameter, in center of plate; 2 clips attached to anterior edge of plate fasten cover slip in position when slide is placed on plate.

l  to clean the counting chamber: after completing the count, remove the cover glass and clean the counting chamber with water or a mild cleaning solution (10% solution of bleach). dry the counting chamber with a soft cloth or wipe, or rinse with acetone.

货号

产品描述

3820

howard mold霍华德霉菌计数板,含50805090

5080

howard thin 28mm×33mm×0.5mm cover slip

5090

howard thick 28mm×33mm×1.0mm cover slip

5070

howard eyepiece micrometer

 

其他计数板

3875

mcmaster egg slide chamber only

4000

nageotte counting chamber,含2cover slips(5400)15411

4001

nageotte counting chamber,含2cover slips(5400)15411

5400

reusable盖玻片,30mm×33mm×0.5mm

5411

disposable cover slips30mm×33mm×0.5mm,约70

3850

palmer nanoplankton counting chamber with 2 盖玻片es

3900

petroff-hausser血球计数板,counting chamber w/2 盖玻片

3920

petroff-hausser血球计数板,counting chamber set with case

3900ng

no grid chamber w/2 盖玻片

3901

10 microns chamber w/2 盖玻片

3902

20 microns chamber w/2 盖玻片

5000

备用盖玻片,20mm×26mm×0.5mm

3800

sedgwick-rafter计数板,counting chamber with 盖玻片

5040

sedgewick rafter盖玻片,25mm×60mm×0.5mm

5060

whipple eyepiece micrometer,直径21mm

3556

speirs-levy eosinophil计数板,counting chamber w/2 盖玻片

5020

备用盖玻片,25mm×33mm×0.5mm

5010

备用盖玻片,25mm×28mm×0.5mm

5030

备用盖玻片,27mm×37mm×0.5mm

5050

petroff-hausser增强型盖玻片(oil immersion)

5051

petroff-hausser盖玻片,20mm×26mm×0.2mm

5075

graduated howard mold cover glass, unlaminated

5075l

graduated howard mold cover glass, laminated

475

type 1 micrometer disc

1406a

type 1 micrometer disc

476

type 2 micrometer disc

1407a

type 2 micrometer disc

477

type 3 micrometer disc

1408a

 type 3 micrometer disc

1409a

type 4 micrometer disc

479

type 5 whipple disc.

480

type 6 cross hair disc.

1427

type 6 cross hair disc

481

type 7 miller disc.

1405a

type 8 micrometer disc

1421a

type 10 micrometer disc.

400

stage micrometer

1400

stage micrometer

1450

"flip" pipette filler

1456

red pipette

1458

white pipette

1505

plastic case with foam insert for safe storage of counting chamber, cover slips, and pipettes

3110

美国hausser bright-line血球计数板,仅counting chamber

3100

美国hausser bright-line血球计数板,含counting chamber2盖玻片

3120

美国hausser bright-line血球计数板,套装

3102

chamber with 2 cover glass (no grid)

3200

phase counting chamber w/2 cover glass (used with phase microscope)

5000

备用cover glass

3510

hausser dark-line 血球计数板,counting chamber only

3500

counting chamber with 2 盖玻片

3520

complete set

5000

备用盖玻片,20mm×26mm×0.5mm

3720

fuchs-rosenthal 血球计数板,counting chamber with 2 cover slips

5000

备用盖玻片,20mm×26mm×0.5mm

 

上海上碧实验仪器有限公司为用户提供优良产品及服务以及唯实求真的原则,多年来为众多机构引荐了大量的高品质仪器及设备,更为其提供了全方位的优良服务,为各机构带来了方便与满意。

其代理产品有:

 美国masterflex蠕动泵
 法国saint-gobain圣戈班管(tygon、norprene、pharmed、spd、viton系列)
 美国gast嘉仕达真空泵、气动马达
 美国eldex柱塞泵
 美国ysi维赛水质分析仪、日本horiba掘场水质分析仪、美国哈希hach浊度仪、德国byk气泡粘度计、  美国cannon粘度计
 美国泰来华顿taylor-wharton液氮罐
 美国plas-labs手套箱
 美国coleparmer超声波细胞破碎仪、洗瓶机,美国labconco洗瓶机
 美国burrell手腕式振荡器
 美国tyler泰勒筛-振荡筛-筛分机

美国p-80橡胶润滑剂、micro-90清洗剂、lf2100清洗剂
包括生命科学仪器、临床检验、理化分析仪器、植物学、农业相关仪器、食品、微生物仪器、通用实验设备、消耗品及试剂,涉及生命科学、制药、食品、饮料、日用化学、化妆品、轻工化工及电子芯片等行业
“服务科学、服务人类”是我们公司的经营理念,不管是从产品质量把关、选型配置,还是凯发app官网登录的售后服务上都是以客户为中心。更多了解请关注凯发app官方网站的凯发app官网登录官网:www.shangbi.com

- - - - - - - - - - - - - - - - - - - - -


标题:
内容:
联系人:
联系**:
email:
公司名称:
联系地址:
 
 
注:1.可以使用快捷键alt s或ctrl enter发送信息!
2.如有必要,请您留下您的详细凯发app官方网站的联系方式!
网站地图